All Sices synchronization controller DST64xx, MCxxx, GCxxx, BTBxxx series are fully disabled for all the main functions of a controller including the following parts:

  • System.
  • Connection.
  • Guard.
  • Auxiliary function.
  • Communicate.
  • CANBUS.
  • Synchronized.

SICES hoà đồng bộ máy phát điện

However, there are still differences between synchronous controllers to show the difference between Sices synchronizing controller TTTT, such as:

  • Sices DST4602 Evolution: The controller Sices uses parallel control of advanced and complex systems, working in island mode and in parallel with mains power.
  • Sices GC400 Mains: Synchronous controller used to manage various synchronous/parallel applications, especially for MPM and MSB standby generators.
  • Sices GC600 Mains: The controller specializes in handling synchronous applications including PLC to fully meet the requirements set forth.
  • Sices MC200: Controller applied by many synchronous generators operating in parallel, managing multiple power sources, can switch power from mains to generator power.
  • Sices MC400: Controller used to manage mains power and switchgear in applications where multiple generators operate in parallel.
  • Sices BTB200: The controller is used to switch and disconnect the busbar, used in cases where it is necessary to divide the common busbar.

Functional comparison of Sices synchronizing controllers DST2602, GC400 & GC600

 CodeName

DST 4602

GC 400

Mains

GC 600

Mains

1Systemxxx
1.1Guardxxx
1.2Enginexxx
1.3Generatorxxx
1.4Main source / BUSxMainsx
1.5Frequencyxxx
1.6Electricxxx
1.8Overviewxxx
1.9Measurex
2Connectionxxx
2.1Main sensorxxx
2.2Detect engine runningxxx
2.3Engine timexxx
2.4Other parameters for the sequencexxx
2.5Closed before stimulationx
2.6Air mixerx
3Guardxxx
3.1Generator protectionxxx
3.1’Current protection
3.2Engine protectionxxx
3.2’Main source protection
3.3Protection measures for D-PROx
3.3’Battery protection
3.4’Other protection
4Auxiliary functionxxx
4.1Planningxxx
4.2Auxiliary functions for enginesxxx
4.3History Diaryxxx
4.5Thresholds when loadingxxx
4.7Equipmentxxx
5Communicatexxx
5.1Serial port 1xxx
5.2Serial port 2xxx
5.3USBxxx
5.4Modemxxx
5.5Ethernetxxx
5.6Si.Mo.Nexx
5.7GPSxx
5.8Mobile networkx
7CANBUSxxx
7.1Engine controllerxx
7.2Voltage regulatorxx
7.3Gas control unitx
8Synchronizedxxx
8.1PMCBxxx
8.2Download functionxxx
8.3Regulationsxxx
8.4Synchronizexxx
8.5Active energy managementxxx
8.6Reactive power managementxxx
8.7Droopxxx
8.8Parallel to the power supplyxxx

References: Sices controller

References: Sices ATS115 configuration


Functional comparison of synchronization generator controllers to grid Sices  MC200 & MC400

Installation codeInstallation name

MC200

MC400

1Systemxx
1.1Guardxx
1.2Engine
1.3Generatorxx
1.4Main source / BUSxx
1.5Frequencyxx
1.6Electricxx
1.8overviewxx
1.9Measure
2Connectionxx
2.1Main sensorxx
2.2Detect engine running
2.3Engine time
2.4Other parameters for the sequencexx
2.5Closed before stimulation
2.6Air mixer
3Guardxx
3.1Generator protection
3.1’Current protectionxx
3.2Engine protection
3.2’Main source protectionxx
3.3Protection measures for D-PRO
3.3’Battery protectionxx
3.4’Other protectionxx
4Auxiliary functionxx
4.1Planningxx
4.2Auxiliary functions for engines
4.3History Diaryxx
4.5Thresholds when loading
4.7Equipmentxx
5Communicatexx
5.1Serial port 1xx
5.2Serial port 2xx
5.3USBxx
5.4Modemxx
5.5Ethernetxx
5.6Si.Mo.Ne
5.7GPSxx
5.8Mobile network
7CANBUS
7.1Engine controller
7.2Voltage regulator
7.3Gas control unit
8Synchronizedxx
8.1PMCBxx
8.2Download functionxx
8.3Regulationsxx
8.4Synchronizexx
8.5Active energy management
8.6Reactive power management
8.7Droop
8.8Parallel to the power supplyxx

Compare the parameters of Sices synchronizing controller

System

The main parts of  Sices synchronizing controller are:

  • Protection (GC315 Link not available).
  • Motor (MC200, 400; BTB200 not available).
  • Generator (BTB200 is Bus A).
  • Mains/BUS (GC250, 315 Link, 400 Mains have mains only; BTB200 is Bus B).
  • Frequency.
  • Electric.
  • Overview (GC250, 315 Link; BTB200 not available).
  • Unit of measure (DST4602 Evolution only).

Connection

  • Main sensor (BTB200 not available).
  • Detects running motor (MC200, 400; BTB200 not available).
  • Motor timing (MC200, 400; BTB200 not available).
  • Other parameters for the sequence.
  • Closure before stimulation (DST4602 Evolution only).
  • Air mixer (DST4602 Evolution only).

Guard

  • Generator protection (DST4602 Evolution, GC250, 315 Link, 400 Mains, 600 Mains only).
  • Current protection (MC200, 400, BTB200 only).
  • Motor protection (DST4602 Evolution, GC250, 315 Link, 400 Mains, 600 Mains only).
  • Mains protection (MC200, 400 only).
  • Protections for D-PRO (DST4602 Evolution only).
  • Battery protection (MC200, 400; BTB200 only).
  • Other protection (MC200, 400; BTB200 only).

Auxiliary function

  • Scheduling (BTB200 not available).
  • Motor auxiliary functions (MC200, 400; BTB200 not available).
  • Historical diary.
  • Thresholds under load (GC250, 315 Link; MC200, 400; BTB200 not available).
  • Equipment.

Communicate

  • Serial port 1.
  • Serial port 2 (GC250 has none).
  • USB.
  • Moden (GC250 not available).
  • Ethernet (GC250 not available).
  • Si.Mo.Ne (Only available at GC315 Link, 400 Mains, 600 Mains).
  • GPS (DST4602 Evolution, GC250 not available).
  • Mobile network (GC315 Link only, 400 Mains).

CANBUS

  • Motor controller (DST4602 Evolution, GC250, 600 Mains only).
  • Voltage regulator (DST4602 Evolution, GC250, 600 Mains only).
  • Gas control unit (DST4602 Evolution only).
  • The CANBUS installation part is an important part, but only the DST4602 Evolution controller is set up to fully install the important CANBUS parts, this represents the most advanced and completeness of the DST4602 Evolution controller compared to the DST4602 Evolution controller. with other controllers of the SICES brand.

Synchronized

  • PMCB (GC250, GC315 Link not available).
  • Load function (GC250, GC315 Link, BTB200 not available).
  • Regulation (GC250, GC315 Link not available).
  • Synchronization (GC250, GC315 Link not available).
  • Active power management (DST4602 Evolution, GC400 Mains, 600 Mains only).
  • Reactive power management (DST4602 Evolution, GC400 Mains, 600 Mains only).
  • Droop (DST4602 Evolution, GC400 Mains, 600 Mains only).
  • Parallel power supply (DST4602 Evolution only, GC400 Mains, 600 Mains; MC200, 400).
  • The level of Sices synchronizing controller likes DST4602 Evolution controller also has more settings than other SICES series of controllers making the controller perform better in almost any use case, which proves for position of the most modern DST4602 Evolution controller to the present time.

If you need more information about generator control panel price or Sices synchronizing controller, please contact us: